Teleflex表示,数据显示其Titan SGS吻合器的效果更好

Teleflex says data shows enhanced outcomes with its Titan SGS stapler

MASSDEVICE 等信源发布 2024-08-21 03:10

可切换为仅中文


Teleflex

Teleflex公司

(NYSE: TFX)

+

+

today announced data from a retrospective analysis linking its Titan SGS stapler to enhanced outcomes.

今天公布了一项回顾性分析的数据,该数据将其Titan SGS订书机与增强的结果联系起来。

Wayne, Pennsylvania-based Teleflex said the data demonstrated improved clinical outcomes and significant procedural efficiency benefits. The analysis compared the Titan SGS stapler to multi-fire surgical staplers in patients undergoing laparoscopic sleeve gastrectomy (LSG).

总部位于宾夕法尼亚州韦恩的Teleflex表示,这些数据表明临床结果有所改善,并且有显著的手术效率益处。该分析比较了腹腔镜袖状胃切除术(LSG)患者的Titan SGS吻合器和多火外科吻合器。

Five surgeons at a Corewell Health Hospital in Grand Rapids, Michigan, conducted the study. They published their findings in the journal Obesity Surgery.

密歇根州大急流城Corewell健康医院的五名外科医生进行了这项研究。他们将研究结果发表在《肥胖手术》杂志上。

Titan SGS is the first and only single-fire surgical stapler designed and indicated for sleeve gastrectomy pouch creation and the only surgical stapler cleared by the FDA for this specific indication, according to a news release. Teleflex acquired the stapler through its 2022 purchase of Standard Bariatrics..

据新闻稿称,Titan SGS是第一款也是唯一一款专为袖状胃切除术袋制作而设计和使用的单火外科吻合器,也是唯一一款经FDA批准用于此特定适应症的外科吻合器。Teleflex通过2022年收购标准减肥药公司收购了订书机。。

The anatomy-based approach of surgical stapling helps surgeons achieve more consistent and symmetrical anatomy with Titan SGS. It features a 23 cm continuous staple line to allow surgeons to plan and place staples in one firing. The stapler eliminates the risk of overlapping staple lines, a known risk factor for leaks..

基于解剖学的手术吻合器方法有助于外科医生使用Titan SGS实现更一致和对称的解剖结构。它的特点是有一条23厘米长的连续钉线,允许外科医生在一次射击中计划和放置钉。订书机消除了钉线重叠的风险,这是已知的泄漏风险因素。。

Teleflex reported results from 807 patients who underwent LSG using the second-generation SGS stapler. It compared them to 3,829 patients who underwent LSG using multi-fire staplers.

Teleflex报告了807名使用第二代SGS吻合器接受LSG治疗的患者的结果。它将他们与3829名使用multi-fire吻合器接受LSG治疗的患者进行了比较。

The company reported a median operative time for Titan that came in eight minutes shorter than the multi-fire staplers. Patients also proved more likely to get discharged within 24 hours of surgery with Titan SGS (89.6%) compared to multi-fire (65%).

该公司报告称,Titan的中位手术时间比多火订书机短8分钟。与多次火灾(65%)相比,使用Titan SGS(89.6%)的患者在手术后24小时内更有可能出院。

Over 30 days, Titan SGS led to fewer readmissions, especially related to nausea and vomiting (1.7% vs. 4.5%). Teleflex also reported a trend toward a reduction in reoperations and leaks by 30 days. Investigators saw a similar rate of post-operative bleeds as well. The study showed no leaks, strictures or post-operative interventions in the Titan SGS cohort..

超过30天,Titan SGS导致再入院率降低,特别是与恶心和呕吐有关(1.7%比4.5%)。Teleflex还报告称,再次手术和泄漏的趋势将减少30天。调查人员也发现了类似的术后出血率。该研究显示,Titan SGS队列中没有泄漏,狭窄或术后干预。。

Investigators note that weight loss at six months was slightly, yet significantly greater in the multi-fire group. However, they say preliminary review of the one-year data showed that this difference diminishes. The authors concluded that “the simplified and efficient stapling process offered by [Titan SGS] has the potential to enhance the safety and effectiveness of LSG, ultimately benefiting patients and healthcare providers.”.

调查人员注意到,六个月时的体重减轻程度略高,但多发性火灾组的体重减轻程度明显更高。然而,他们表示,对一年数据的初步审查表明,这种差异正在缩小。作者得出结论,“Titan SGS提供的简化高效的装订过程有可能提高LSG的安全性和有效性,最终使患者和医疗保健提供者受益。”。

“Based on the real-world evidence from this and other studies completed to date, patients and surgeons can be confident in the use of this first and only stapler specifically designed for sleeve gastrectomy pouch creation,” said James Ferguson, president and GM, Surgical, at Teleflex.

Teleflex总裁兼外科总经理詹姆斯·弗格森(JamesFerguson)表示:“根据迄今为止完成的这项研究和其他研究的真实证据,患者和外科医生可以自信地使用这种第一个也是唯一一个专门为袖状胃切除术袋制作而设计的订书机。”。